Locate - 34 UtiliGuard™ Series Operator’s Manual
Locate Active Signals
CMW
®
Technique
1. Facing away from the transmitter, walk in an arc approximately 25’ (A, 7.5 m) around transmitter, as
shown above.
2. Rotate the receiver and observe the screen:
Target is located where signal response
(1) is strongest. Signal strength is shown
graphically as well as numerically.
Adjust gain as needed to maintain signal
strength. Gain is shown graphically as
well as numerically (6).
The Compass Line (2) shows the direction
the cable runs.
Move in the direction of the center arrows.
When the arrows form a diamond (3), the
target is located.
AutoDepth reading (4) will appear when
target is correctly located. If operating in
Manual depth mode, press and hold the
Depth button.
Use Current Measurement (5) to identify target cable. Current on the target cable should be higher
than current on another cable that is picking up signal inductively from target cable.
3. Continue to trace the cable and observe depth estimates every few paces.
4. Retrace the cable and mark with appropriate flags or paint.
IMPORTANT: Follow steps below for all types of active location. For reference, the illustration above
shows direct connection method. If using broadcast induction, ensure that transmitter is in line with and
above suspected cable, as shown on previous page.